placeholder · competitor · tiimg.tistatic.com (TradeIndia)Passive Broad Band Harmonic Filter
A passive broad-band harmonic filter (BBF) is a wide-bandwidth LC filter that attenuates a continuous band of harmonic frequencies rather than being sharply tuned to single orders, avoiding the resonance problems of conventional shunt-tuned filters.
Overview
A passive broad-band harmonic filter (BBF) is a wide-bandwidth LC filter that attenuates a continuous band of harmonic frequencies rather than being sharply tuned to single orders, avoiding the resonance problems of conventional shunt-tuned filters. ACE's broadband design (existing site) pairs a series low-pass section with a shunt high-pass section so the filter behaves as the local source for the load's harmonic demand, cutting harmonics at the supply end while improving system power factor — a 'two-in-one' benefit. Because it uses no electronics, control algorithms or firmware, it is rugged, maintenance-free, reliable and inexpensive, and is easy to retrofit near the load to reduce bus-duct I²R losses and skin effect. Buyers choose the broad-band variant over simple shunt-tuned filters where they want stable, resonance-free harmonic mitigation across many 6-pulse VFD loads without the cost and complexity of active solutions.
Specifications
| Power/HP range | typically 5 HP to ~500 HP per unit (extendable to MW-class for large drives) |
|---|---|
| Voltage class | LV 380-480 V / 415 V / up to 690 V, 3-phase, 50/60 Hz |
| Topology | broadband series low-pass + shunt high-pass LC (not single-frequency tuned) (existing site) |
| THDi | typically reduced to ~5-8% at full load to meet IEEE-519 |
| Configuration | 3P3W (balanced load) and 3P4W (corrects up to 25% unbalance) (existing site) |
| Resonance | broadband response avoids resonance with transformer/source impedance (existing site) |
| Components | fully passive — reactors + capacitors, no electronics or control firmware (existing site) |
| Mounting/enclosure | frame-mount IP00 or cabinet IP20/IP54; install close to load |
| Cooling | natural / forced air |
| Applicable standards | IEEE-519, IEC 61000-3, IS 2026 / IEC 60076 (reactors) |
Applications
- Front-end six-pulse DC rectifiers (existing site)
- VFDs and motor applications (existing site)
- Automation equipment (existing site)
- HVAC equipment using motor drives (existing site)
- Waste-water / effluent treatment plants (existing site)
- Battery chargers (existing site)
Request a quote — Passive Broad Band Harmonic Filter
Tell us your application and ratings. Our engineering team replies within one business day.
More in Harmonic & Electric Filters

Passive Harmonic Filter
A passive harmonic filter is a line-side LCL network of reactors and tuned capacitors connected ahea

Active Harmonic Filters
An active harmonic filter (AHF) is a shunt-connected IGBT PWM power converter that continuously meas

Sine Wave Filters
A sine-wave (sine) filter is a low-pass LC filter fitted on the output of a PWM variable-frequency d