ACE Regenerative Systemsplaceholder · competitor · 5.imimg.com (IndiaMART)
Power Electronics & Conditioning

ACE Regenerative Systems

IGBT-based active front-regenerates test power bonly the system's active

A regenerative (active) load system replaces a conventional resistive/reactive load bank used to test equipment such as alternators, motors, transformers, battery chargers, DG sets and rectifiers.

Overview

A regenerative (active) load system replaces a conventional resistive/reactive load bank used to test equipment such as alternators, motors, transformers, battery chargers, DG sets and rectifiers. Instead of dissipating the full test power as heat in resistor or salt-water banks, ACE's IGBT-based system is grid-tied ('grid-locked') and feeds the test power back into the user's own 3-phase grid for reuse — so the source only has to supply the system's loss (efficiency-loss) power rather than the full load power. Buyers choose it to drastically cut the energy wasted during full-load testing, avoid the heat and footprint of dump-load banks, and obtain a controllable, dynamic electronic load with low injected current harmonics. (Existing site: IGBT-based, regenerates power for active use, takes only system active-loss power from the source, current harmonics THDi < 10%.)

Specifications

Standard parameters — confirmed on enquiry
TopologyIGBT-based active front-end, grid-tied / grid-locked regeneration (existing site)
Functionregenerates test power back into user's 3-phase grid (existing site)
Source drawonly the system's active loss power, not full load power (existing site)
Current harmonicsTHDi < 10% (existing site)
Power ratingbuilt to test-target rating (class: tens of kW to MW range)
Grid connectionthree-phase, 415 V class (50/60 Hz)
Load type emulatedactive (real) power load, dynamically controllable
Controldynamic / programmable load profile
Applicable standardsgrid-interface / harmonic limits per IEEE-519 / IEC 61000 class

Applications

  • Full-load testing of alternators and generators
  • Motor load / endurance testing
  • Testing power transformers, rectifier units and battery chargers
  • DG-set load testing without resistive dump load
  • Energy-saving replacement for resistive / salt-water load banks
Built to specification. Custom ratings, voltages and enclosures available — share your single-line diagram and duty cycle and we'll engineer the unit to match. Specifications shown are standard ranges and are confirmed against your requirement on enquiry.

Request a quote — ACE Regenerative Systems

Tell us your application and ratings. Our engineering team replies within one business day.