Line Reactors / Inductors

typically 3% or 5% (linematched to VFD/drive ful230 / 415 / 480 / 600 /

A line reactor (input/AC line choke) is a three-phase series inductor installed between the supply and a VFD, rectifier, soft-starter or other non-linear load.

Overview

A line reactor (input/AC line choke) is a three-phase series inductor installed between the supply and a VFD, rectifier, soft-starter or other non-linear load. It limits the rate of current rise, buffers the drive from voltage transients, notching and sags, and reduces harmonic current drawn from the line — a 3–5% impedance reactor typically cuts input current THD from roughly 80–100% down to about 35–40%, improving true power factor and protecting both the drive's DC-bus capacitors and upstream equipment. The same construction used on the drive output (as a load reactor) limits dV/dt and reflected-wave stress on motor cables and windings. ACE manufactures these as dry-type, naturally-cooled, copper- or aluminium-wound reactors on laminated silicon-steel cores, rated to the drive's full-load current with impedance specified as %Z (Uk). Buyers choose ACE for reactors sized to the actual operating current so the rated impedance is delivered where it matters.

Specifications

Standard parameters — confirmed on enquiry
Impedance (%Z / Uk)typically 3% or 5% (line buffering vs. harmonic mitigation)
Rated current (A)matched to VFD/drive full-load current (FLA)
Inductance (mH) derived from %Z, current and frequency
Voltage class230 / 415 / 480 / 600 / 690 V up to ~1140 V
Frequency50 / 60 Hz (400 Hz on request)
Phasesthree-phase (single-phase on request)
THD reductioninput current THD reduced to ~35–40% at 3–5% Z
Insulation classup to Class H; temperature rise to spec
Coolingnatural air (dry type); Mounting: panel / floor; Enclosure: open IP00 or enclosed
Applicable standardsIEC 60076-6, IEEE-519, UL/IS as required

Applications

  • Input (line-side) protection and harmonic reduction for VFDs / AC drives
  • Output (load-side) reactors limiting dV/dt and reflected-wave on long motor cables
  • Soft-starter and rectifier-bridge input buffering
  • Reducing voltage notching and nuisance tripping between multiple drives
  • DC-bus capacitor and semiconductor protection in drive systems
Built to specification. Custom ratings, voltages and enclosures available — share your single-line diagram and duty cycle and we'll engineer the unit to match. Specifications shown are standard ranges and are confirmed against your requirement on enquiry.