Neutral / Earthing / Zig-Zag Transformersplaceholder · competitor · indiamart.com (Kotia Transformers Pvt Ltd, Kolkata)
Transformers

Neutral / Earthing / Zig-Zag Transformers

LV up to MV (e.g. 415 V zig-zag (interconnected e.g. 10 s, 30 s, or cont

Neutral / earthing / zig-zag transformers create an artificial neutral (ground reference) on a three-phase system that has no accessible neutral — most often a delta-connected or otherwise ungrounded supply — so the system can be earthed and ground faults detected and cleared safely.

Overview

Neutral / earthing / zig-zag transformers create an artificial neutral (ground reference) on a three-phase system that has no accessible neutral — most often a delta-connected or otherwise ungrounded supply — so the system can be earthed and ground faults detected and cleared safely. The classic form is the zig-zag (interconnected-star) transformer: each limb carries interleaved sections of two phases so the winding presents high impedance to normal balanced (positive/negative-sequence) currents but a low zero-sequence impedance path to ground, letting it pass earth-fault current while drawing only small magnetizing current in healthy operation. The derived neutral is usually taken to ground through a Neutral Grounding Resistor (NGR) or reactor to limit fault current to a chosen value. These units are short-time rated (sized to carry full fault current for a defined time such as 10 s or 30 s) and are specified by system voltage, fault current, duration and zero-sequence impedance. A buyer needs one wherever an ungrounded/delta system must be solidly or impedance-earthed for protection.

Specifications

Standard parameters — confirmed on enquiry
System voltage / voltage classLV up to MV (e.g. 415 V to 33 kV)
Connectionzig-zag (interconnected star) or grounded wye-delta
Continuous neutral current rating and ground-fault (short-circuit) current
Short-time rating / duratione.g. 10 s, 30 s, or continuous
Zero-sequence impedanceengineered to set fault-current division
Phasesthree-phase
Frequency50 / 60 Hz
NGR / NGT (resistor or reactor) integration to limit fault current
Cooling/constructiondry-type or oil-filled; indoor/outdoor
Insulation/thermal class and BIL per voltage class
StandardsIEC 60076-6 / IEEE C57.32 / IEEE C62.92; IS where applicable

Applications

  • Deriving a neutral on delta / ungrounded three-phase systems
  • Resistance- or reactance-earthing (with NGR/NGT)
  • Ground-fault detection and protection coordination
  • Generator and transformer-secondary grounding
  • Industrial, distribution and utility earthing schemes