placeholder · competitor · indiamart.comACE Line Choke
The ACE Line Choke is ACE's series line/AC choke for limiting current and mitigating harmonics on the supply side of non-linear loads and capacitor banks.
Overview
The ACE Line Choke is ACE's series line/AC choke for limiting current and mitigating harmonics on the supply side of non-linear loads and capacitor banks. As the existing site frames it, the rising use of modern electronics raises harmonic current demand (THDi), which raises supply voltage distortion (THDv); this distortion can resonate with shunt PFC capacitors and cause harmonic amplification, capacitor/transformer/line overloading, voltage distortion and interference with metering and controls. The line choke is connected in series to add inductive reactance that smooths current rise, attenuates harmonic and switching components, and protects downstream capacitors and equipment. ACE builds these as dry-type, naturally-cooled, H-class wound reactors on laminated cores, rated to the line/load current with impedance or inductance specified per the application. Buyers choose ACE for a robust series choke matched to their harmonic and current-limiting requirement.
Specifications
| Inductance (mH) / impedance (%Z) specified per application | |
| Rated current (A) | line/load current plus harmonic loading |
|---|---|
| Voltage class | LV (e.g. 415 / 440 / 690 V) as specified |
| Frequency | 50 / 60 Hz |
| Phases | three-phase (single-phase on request) |
| Harmonic / current-rise limiting; high-harmonic-environment capability | |
| Insulation | Class H; low noise |
| Cooling | natural air (dry type); low watt-loss per kg |
| Mounting | panel / floor; Enclosure: open IP00 / enclosed as specified |
| Applicable standards | IEC 60076-6, IEEE-519, IS/IEC |
Applications
- Series line-side choke for harmonic and current-rise limiting (existing site context)
- Protecting shunt PFC capacitors from resonance and overloading (existing site context)
- Input buffering for rectifiers, drives and non-linear loads
- Reducing voltage distortion and metering/control interference (existing site context)
- Power-conditioning and line-pollution mitigation
Request a quote — ACE Line Choke
Tell us your application and ratings. Our engineering team replies within one business day.
More in Reactors & Inductors

Buck Boost Inductors
Buck-boost inductors are the energy-storage chokes at the heart of buck, boost and buck-boost switch

Filter Inductors
Filter inductors are series chokes used to smooth current, attenuate ripple and harmonics, and shape

Line Reactors / Inductors